How Many Elevators Should Your Building Have? The thinking behind the count.
A visitor enters the polished lobby of a soaring downtown skyscraper and quickly makes their way to the bank of elevators. Headed to a job interview on the 19th floor, they push the up button and wait. And wait. One finally arrives, but it’s already full.
Unable to stand idly by, they glance at their watch and start the immediate search for a stairway. It’s going to be a lengthy climb to floor 19, which gives them ample time to wonder about the office space priorities of their potential employer.
While this scenario is fiction, our daily reliance on elevators is not. These machines are so embedded in our lives that we rarely even think about them – except when they’re out of service, painfully slow, or overwhelmed with passenger demand. In fact, it’s when that invisible vertical transit contract between traveler and hardware is broken that we all take notice and become immediate experts on what’s acceptable, and what’s not, for how many working elevators should be in place.
So, let’s follow that script for a second – what if you were the one responsible for determining how many elevators a new building should have? How would you decide the actual count, and what factors would play into your figures determining how many to include?
As it turns out, this is not a guessing game, but a careful calculation based on several factors.
When the Total Elevator Count is Off
When a building is designed and constructed with too many – or, more likely, too few – elevators, there are economic and practical impacts in both directions. If a determination is later made to increase the count, this would not be an easy problem to correct. Elevators travel through continuous vertical hoistways integrated into a building’s core structure. Trying to alter this after construction has been completed can be exceptionally complicated, invasive, and expensive, if not impossible. Said another way: it’s not likely to happen.
As any building resident or visitor would attest, having too few elevators is a big problem. If people can’t get to their destinations in a reasonable amount of time, or are constantly having to deal with overcrowding, they’ll become frustrated. Some of the issues that are likely to arise include:
-
- Long wait times: During peak rush hours (morning arrival, lunch, or evening departure), passengers can face aggravating long lines and extended wait times in the lobby.
- Operational inefficiencies: If service elevators are slow or down, janitorial staff, delivery personnel, and building maintenance teams can end up competing with building tenants for rides within elevators that are not designed to transport bulky equipment.
- Expected downtime: Elevators occasionally have to be taken out of service for routine maintenance, inspection, or service. If there aren’t enough elevators in a building to reasonably manage traffic when one is being worked on, it’s a problem.
Potential higher tenant turnover: High-end tenants who pay premiums for building perks and efficiency expect that the systems designed to get them where they need to be are reliable and efficient. Insufficient elevator service, be it slow response times or unavailability, makes it possible they’ll choose a different building.
While having a surplus of elevators is certainly better than having too few, there are factors architects and building owners should consider, including:
- Increased construction and capital costs: Elevator systems contribute to the capital expense of any new construction project.
- Loss of leasable area: Elevator hoistways extend through every floor, reducing a building’s usable square footage and income potential.
- Maintenance and operating expenses: Every elevator system needs regular inspection and maintenance.
Factors Driving the Number
Stakes are high for getting the elevator count right during the building design and blueprint phase. But what factors go into getting that number right?
Here’s a summary of considerations for a typical office building:
- Building population demographics. This is derived by looking at the usable area within a building divided by the estimated density for that space. For instance, Class A buildings – such as those used by corporate HQs or white shoe investment or law firms, might have an average density of one person per 100 to 120 square feet. That means a 100,000 square foot office building may have about 1,000 workers.
- Peak traffic demand. Once building population has been estimated, the next factor is determining how many of those people within a five-minute window are likely to use an elevator during peak times, such as a morning arrival rush, lunch break, or evening departure slots. or a building with 5,000 people, that might be 600 to 750 people needing access to the elevators during a peak five-minute window.
- Elevator cycle time (commonly referred to as round-trip time, or RTT). This is the average time it takes one elevator to load passengers at the lobby, travel up, make a series of stops, unload, and return to the starting point. The RTT industry formula used is based on the work of Dr. Gina C. Barney, a renowned vertical transportation consultant, and engineer and author S.M. dos Santos.
Their equation factors in:
- Passengers per trip: This is typically counted at 20% below what a car may be able to carry (more on this in the elevator capacity section).
- Highest probable floor: This is a probability factor of how high up in a building the elevator is likely to travel before heading back to the lobby.
- Expected stops: Estimates how many different stops the elevator will make based on passenger count on board.
- Travel time per floor: This is inter-floor distance divided by an elevator’s rated speed.
- Time per stop: Accounts for time needed for doors opening, closing, acceleration, and deceleration of the elevator.
- Passenger transfer time: How much time is needed for a passenger to board or exit the car.
- Feasibility of optimization. Installing a destination dispatch system in a high-rise building provides an opportunity to group and consolidate passengers headed to the same or nearby floors into a single elevator to improve efficiency and throughput of traffic.
How Building Type Can Impact Elevator Count
While the formula above can be applied to office buildings, here are some other factors that come into play for other elevator use cases:
- Hotels: Capacity and peak need estimates may vary based on check-out times (typically 10 AM to 12 PM). More so, service elevators for housekeeping, etc. may be included in the mix as well for a separate count.
- Residential: Peak usage requirements are lower than office buildings (). Also, designers may need to dedicate at least one elevator for moving without disrupting transit for other residents.
- Hospitals: Total counts may vary between different types of elevators, including:
- Emergency / trauma: Connected directly to helicopter pads, emergency rooms, and intensive care units (ICUs).
- Patient transport: Must also be sized to accommodate oversized hospital beds, life-support equipment, and supporting medical teams.
- Visitors: Most typical use is going between lobby traffic and patient floors.
- Stadiums: In some modern venues, elevators are specifically used for ADA accessibility, VIP and/or luxury suite access, freight for food, events, media, etc. High-capacity escalators do the heavy lifting of getting most fans who do not need to use ramps to their seats.
What Really Counts with Elevators
There’s a lot of thinking, formulas, and other considerations that go into the elevator count in modern new construction. But despite all the rigor and analysis honed over the years, it’s still possible to get it wrong.
So, the next time you find yourself waiting for an elevator longer than expected, do your own calculations on what you think the count should be.
It’s that, or hit the stairs.
Sources:
https://adsimulo.com/elevator-handling-capacity/
https://liftescalatorlibrary.org/paper_indexing/papers/00000171.pdf